Solution · Solar and self-consumption

Do not let the solar ruin your consumption charts

One net number on the grid input cannot answer "how much did I actually buy" and "how much did I give away" — it answers their difference. rbAmp STD counts import and export separately, on the same input, and BASIC measures the loads that are supposed to be eating the surplus.

Three things a net reading cannot tell you

What you bought, separately from what you sold

A net value is one number for two events. Billing, payback and self-consumption are all ratios between them — the difference alone does not contain them.

Where the surplus actually went

The inverter knows what it generated. It does not know whether the water heater took the midday surplus or the grid did.

Whether the count survived the night

A counter that restarts at zero after a power cut turns a month of data into an estimate.

What measures what

Two jobs, two modules, one bus.

  • STD on the grid input — the meter. Import and export are kept as separate energy counters per current channel, written to the module's own storage every second, so a controller reboot or a power cut does not restart the count. Single-phase (STD-UI1) or three-phase (STD-U3I3).
  • STD on the inverter — generation on its own channel. The same module family, a second measuring point, so generation and consumption are two measurements and not one derived from the other.
  • BASIC on the loads that should take the surplus — water heater, heat pump, car charger. One channel per load, clip-on clamps, nothing cut in the wiring.
  • Everything on one I²C bus, one controller. Each module carries its own address, so the grid input, the inverter and the loads are separate records, not one blended total.

Accuracy is specified per model and, for BASIC, per clamp rating: see the STD specification and the accuracy table on /products/basic.

How the numbers leave the panel

A worked installation

  1. Start at the grid input. One STD there gives you the two counters the net meter was hiding. If the house is three-phase, this is the three-phase module — per-phase import and export, not a sum.
  2. Add the inverter as a second measuring point. Generation measured on its own channel is independent of what the inverter reports about itself.
  3. Then the loads, in order of appetite. Water heater first, then the heat pump, then the car. Each one answers "did the surplus go here?" with a curve instead of an assumption.
  4. Keep one controller. All of it is the same bus; growing the installation is adding modules, not another controller and not another integration.

STD modules → · Single-phase in the shop → · Three-phase in the shop →

When the site is bigger than one cabinet

Several cabinets mean several controllers today, each one complete and reporting on its own. One synchronized view across them is what the RBgrid hub is for, and it is in development.

Read before you buy

Count both directions.

One STD on the grid input answers the question the net meter was averaging away. The loads can follow later.